Please scroll to view all SSI Converters and Interfaces
|
IV 251
-
SSI » Analogue and SSI » Serial |
IV-251 Specifications
|
|
Signal converters IV-251, ZU-251 and IP-251are suitable to translate any angular or positional information from an encoder or a linear scale into an analogue signal or a serial or a parallel data format. All converters are designed for a 18-30 volts DC power supply.
- Signal converter suitable for use with all SSI type sensors and absolute encoders, either in Master mode or in Slave mode
- Analogue outputs +/- 10V, 0-20 mA or 4-20 mA, proportional to the encoder position
- RS 232 and RS 485 serial interface for readout of the actual encoder position
- Easy to set up by simple TEACH procedure, or by PC (operator software included)
- Free scaling, programmable linearisation curves etc.
|
|
ZU 251
-
Incremental count » Analogue and Serial |
ZU-251 Specifications
|
|
Signal converters IV-251, ZU-251 and IP-251are suitable to translate any angular or positional information from an encoder or a linear scale into an analogue signal or a serial or a parallel data format. All converters are designed for a 18-30 volts DC power supply.
- Signal converter suitable for use with all incremental encoders, proximitiy switches etc. either with TTL/RS422 output or with HTL (10-30V) output
- Analogue outputs 10V, 0-20 mA or 4-20 mA, proportional to the encoder position
- RS 232 and RS 485 serial interface for readout of the actual encoder position
- Easy to set up by simple TEACH procedure, or by PC (operator software included)
- Free scaling, programmable linearisation curves etc.
|
|
IP 251
-
SSI » Parallel, SSI » Serial, RS 232 » Parallel |
IP-251 Specifications
|
|
Signal converters IV-251, ZU-251 and IP-251are suitable to translate any angular or positional information from an encoder or a linear scale into an analogue signal or a serial or a parallel data format. All converters are designed for a 18-30 volts DC power supply.
- Signal converter suitable to convert SSI data from an absolute encoder or sensor to parallel data
- Master and Slave operation Also suitable for conversion of serial RS232 data to a parallel data format
- 25 bits parallel outputs, push-pull and short-circuit-proof, programmable output codes: Binary, Gray or BCD
- RS232 serial link for readout of sensor data
- Multiple facilities for scaling and linearisation of parallel output data See “NT251” for 115/230 VAC supply
|
|
GI 210
-
Changeover switch for two SSI encoders |
GI-210 Specifications
|
- Contactless and bounce-free commutation of all signals via remonte 24 volts control signal
- Automatic sychronisation of the changover point to next SSI transmission pause
- Cascadable for more SSI encoders
- All connections via screw terminal strips
- Slim and space-saving housing for DIN rail mounting

|
|